Numerical analysis on energy saving potential for independent temperature control of each supply air inlet

Pris29 kr
ForfattereXiaoliang Shao, Xiaojun Ma, Xuan Jiang, Xianting Li
InstitusjonDepartment of Building Science, School of Architecture, Tsinghua University, China
Publiseringsår2011
Nøkkelordnumerical simulation, temperature control strategy, non-uniform environment, energy saving, air-conditioning
ISBN/ISBN29788251928120/
RedaktørVojislav Novakovic, Sten Olaf Hanssen, Hans Martin Mathisen
SpråkEnglish


Pris: 29,-



Abstrakt

Usually, it is only a few persons occupy a certain local area in a room for most of the time. In this case it is enough to just satisfy the thermal comfort of this local area rather than the whole space. In this paper, the energy saving potential by independent temperature control of each supply inlet is numerically studied based on a typical meeting room. 4 cases, i.e. 4 persons, 12 persons, 20 persons and 24 persons are set up to explore the effect under different scenarios. It is concluded that: (1) Compared with the uniform temperature control method, the energy saving can be realized at a certain degree with the satisfaction of occupied area by using the method of independent temperature control; (2) As the number of occupants increases, the difference of averaged supply air temperature between the independent control and uniform control schemes will be decreased and the energy saving potential will decrease; (3) For a fixed scenario, the different energy saving can be achieved under different schemes of supply air temperatures, where a certain optimization method is needed to determine the optimal supply air temperature. The preliminary analysis is supposed to provide reference to the creation of energy efficient environment by non-uniform air distribution.

Referanser

Chen, Q. Y. And Xu, W. (1998) A zero-equation turbulence model for indoor air flow simulation, Energy and Buildings, 28, 137-144

Heiselberg, P. (1996) Room air and contaminant distribution in mixing ventilation, ASHRAE Transactions, Volume 102, 332–339

Melikov, A.K., Cermak, R. and Majer, M. (2002) Personalized ventilation: evaluation of different air terminal devices. Energy and Buildings, Volume 34, 829–836

Melikov, A.K. (2004) Personalized ventilation, Indoor Air, Volume 14 (Suppl 7), 157–167 Nielsen, P.V. (2000) Velocity distribution in a room ventilated by displacement ventilation and wall- mounted air terminal devices, Energy and Buildings, Volume 31, 179–187

Xing, H. and Awbi, H.B. (2002) Measurement and calculation of the neutral height in a room with displacement ventilation, Building and Environment, Volume 37, 961-967

Xu, L. (2003) Effectiveness of hybrid air conditioning system in a residential house, Ph.D. Thesis, Waseda University, Japan