Validating the thermal behavior of an open-plan office in an innovative large scale commercial building

Pris29 kr
ForfattereFlorian Judex, Renate Teppner
InstitusjonAustrian Institute of Technology, Energy Department, Sustainable Building Technologies
Publiseringsår2011
Nøkkelordmonitoring, thermal behaviour, indoor air temperatures, linear data models
ISBN/ISBN29788251928120/
RedaktørVojislav Novakovic, Sten Olaf Hanssen, Hans Martin Mathisen
SpråkEnglish


Pris: 29,-



Abstrakt

The 7.500 m² office building ENERGYbase in Vienna, Austria, was planned and built satisfying the “passive house” standard. The building utilizes innovative façade design as well as concrete core activation (CCA) supplied by heat pumps, solar heating and groundwater. Furthermore, the ventilation and air-conditioning (HVAC) systems are based on solar heating and solar cooling, with the heat pumps as backup. Approximately 500 sensors were installed for permanent monitoring in the whole building. A 250 m² open-plan office, directly influenced by the south-oriented façade, was chosen to assess the thermal comfort in the building with respect to planned uniformity objectives. The aim was to examine whether the indoor air temperature in the selected office can be deduced from the 20 permanent surface temperature sensors and the 4 permanent illumination sensors.
Additional 49 air temperature sensors, one glass surface temperature sensor and 19 air velocity sensors were placed within the office. Most of the sensors were freely suspended, with a few in the overflow ventilation area and at air openings. Measurements were recorded every minute for approximately four months (July through November 2009). Linear statistical models were chosen to determine a direct relation between permanent and temporary monitoring.
The collected data proved that the planned thermal homogeneity of the room air was nearly reached, showing increased sensitivity to solar radiation close to façade during the summer-winter transitional period. Consequently, the data from permanent and temporary sensors were well correlated, allowing good air temperature approximation based upon the wall sensor readings in the room.
As part of prospective weather predictive control strategies the linear models used for approximating room air temperatures via recorded wall temperatures and illumination values will be implemented to improve the current building control strategies, since they are a viable state observer for the actual room air temperature.


Referanser

Judex, F., Kremen, M., Selke, T., Teppner, R.; ENERGYbase: Monitoring of the Reference Room in the Office Complex of the Future, Proceedings EuroSun 2010 – International Conference on Solar Heating, Cooling and Buildings, Graz, Österreich; 28.09.2010 - 01.10.2010

Preisler, A., Krenn, C., et al; Sunny Research, Berichte aus Energie- und Umweltforschung des BMVIT, 41/2005

Selke, T., Preisler, A., Schneider, U.; ‘ENERGYbase – Sunny Office Future’, Eurosun 2008, 1st International Conference on Solar Heating, Cooling and Buildings, Lisbon, 7th to 10th October 2008, Book of Abstracts, Nr. 357

Selke, T., Preisler, A., Teppner, R.; Visionen werden wahr: ENERGYbase - sonnige Bürozukunft, Expertenforum Beton – Heizen + Kühlen mit Beton – Klimawandel fordert Baukonzepte (2009), S. 42 – 44, Zement + Beton Handels- und Werbeges.m.b.H. im Auftrag der Österreichischen Zementindustrie.

Teppner, R., Preisler, A., Selke, T.; ENERGYbase: Einsatz moderner Simulationswerkzeuge bei der wissenschaftlichen Planungsbegleitung, Proceedings of the ANSYS Conference & 3. CADFEM Austria Users\' Meeting, Wien, Österreich; 24.04.2008.